Recruitment

Recruitment Status
Recruiting
Estimated Enrollment
Same as current

Summary

Conditions
  • Deep Vein Thrombosis
  • Pulmonary Embolism
  • Venous Thromboembolism
Type
Interventional
Phase
Not Applicable
Design
Allocation: N/AIntervention Model: Single Group AssignmentIntervention Model Description: IVD Performance Evaluation StudyMasking: None (Open Label)Primary Purpose: Diagnostic

Participation Requirements

Age
Between 18 years and 125 years
Gender
Both males and females

Description

This is a performance evaluation study designed to assess the precision and accuracy of the LumiraDx Point of Care (POC) D-Dimer test when used in patients presenting with symptoms of Venous thromboembolism (VTE), which mainly comprises deep vein thrombosis (DVT) or pulmonary embolism (PE). The Lumi...

This is a performance evaluation study designed to assess the precision and accuracy of the LumiraDx Point of Care (POC) D-Dimer test when used in patients presenting with symptoms of Venous thromboembolism (VTE), which mainly comprises deep vein thrombosis (DVT) or pulmonary embolism (PE). The LumiraDx POC D-Dimer test is a quantitative immunoassay providing results in under 10 minutes. The accuracy of the LumiraDx POC D-Dimer test will be assessed using capillary whole blood, venous blood, and plasma samples, by comparison to the D-Dimer results obtained from the same individuals as analysed by trained laboratory professionals using a reference device. The results of this study are intended to be used for regulatory filings for use as an in vitro diagnostic test in the European Union (EU) and other relevant geographies. Adult males and females presenting to the study sites with symptoms of VTE will be included in the study. Approximately 1000 subjects will be recruited in total. An initial analysis will be completed on the first 200 patients to determine accuracy of the LumiraDx D-Dimer test versus the reference method. The study will continue until 1000 patients are recruited and with a minimum of 120 confirmed VTE events, in order to complete retrospective analysis using the LumiraDx D-Dimer cut-off for exclusion of VTE. Once consent is obtained, blood tube samples will be drawn and finger-stick samples of capillary blood will be taken from the subject, these will be applied directly to unique test strips for immediate measurement of D-Dimer on the LumiraDx POC D-Dimer test. The D-Dimer results obtained via the LumiraDx D-Dimer test will be used in a set of comparative analyses designed to determine the performance characteristics of the test. This study is an observational, cross-sectional design. As an observational study of an investigative device, results obtained during the course of the study will not inform or alter patient management or treatment decisions in any way.

Tracking Information

NCT #
NCT04737954
Collaborators
Not Provided
Investigators
Principal Investigator: Richard Body Professor of Emergency Medicine