Recruitment

Recruitment Status
Recruiting
Estimated Enrollment
Same as current

Summary

Conditions
  • Hemorrhage
  • Otorhinolaryngologic Diseases
  • Postoperative Hemorrhage
  • Postoperative Pain
  • Surgery- Complications
  • Tonsillectomy
  • Tonsillitis Chronic
Type
Interventional
Phase
Not Applicable
Design
Allocation: RandomizedIntervention Model: Parallel AssignmentIntervention Model Description: Two groups of participants will receive different interventions. One arm will receive the standard of care ( electrocautery) and the other group will receive the BIZACT method of tonsillectomy. The group allocation will be carried out by stratified randomization.Masking: Single (Participant)Masking Description: The participant will not be aware of the arm that the participate will be placed in- i.e. whether the tonsillectomy was carried out by electrocautery or using the BiZact devicePrimary Purpose: Treatment

Participation Requirements

Age
Younger than 18 years
Gender
Both males and females

Description

Tonsillectomy is the second most common pediatric surgical procedure, with more than 280,000 performed in children under the age of 15 in the United States in 2010. The most common indications for tonsillectomy in children include recurrent infections and obstructive sleep apnea. While tonsillectomy...

Tonsillectomy is the second most common pediatric surgical procedure, with more than 280,000 performed in children under the age of 15 in the United States in 2010. The most common indications for tonsillectomy in children include recurrent infections and obstructive sleep apnea. While tonsillectomy in the pediatric population is generally safe and well-tolerated, post-operative complications are not uncommon, with post-operative pain, respiratory compromise, and post-tonsillectomy hemorrhage being chief among them. Post-operative pain has been described as the main morbidity associated with tonsillectomy and is often ineffectively controlled. Pain beyond the initial 24-hour post-operative period has been noted to be worse with the use of electrocautery when compared to cold-knife dissection and snare tonsillectomy, perhaps attributable to the high levels of heat (400 °C to 600 °C) applied directly to the tonsillar area. Yet electrocautery remains one of the most frequently utilized tools due to its hemostatic effects through vessel coagulation at the time of dissection. Still, a recent large meta-analysis reported the rates of primary post-tonsillectomy hemorrhage (bleeding within the first 24 hours) at 2.4% and secondary post-tonsillectomy hemorrhage (beyond 24 hours) at 2.6%, suggesting that bleeding after tonsillectomy remains a relatively common occurrence. The search for a methodology that improves post-operative pain without increasing the risk of post-operative hemorrhage remains an active area of research. Coblation, which creates an ionized plasma layer by passing a bipolar radio-frequency current through a medium of saline, offers another approach. The saline irrigation results in much less heat when compared to monopolar cautery, measuring approximately 40°C to 70°C. Coblation can be used in both subcapsular and intracapsular fashion. Subcapsular tonsillectomy with coblation has demonstrated a minimal decrease in pain, and may result in slightly higher rates of post-operative hemorrhage. It has been pointed out that bipolar cautery could result in lower thermal injury and reduced blood loss, however tonsillectomy using traditional bipolar forceps leads to longer operative times. One group found that the use of BiClamp, a bipolar vascular sealing device originally designed for thyroidectomy, provided decreased operative times and less intraoperative bleeding compared to electrocautery. They noted, however, instances of posterior pillar perforation, which they attributed to curvature of the device that was designed for thyroid surgery, making dissection of the superior pole more difficult. Medtronic has now developed a similar device designed for use in tonsillectomy with a curved jaw meant to follow the contour of the tonsillar bed. In its marketing material for the recently developed BiZact , Medtronic describes a bipolar device that continuously measures the impedance of clamped tissue, adjusting energy levels in real-time and automatically stopping energy delivery when a seal is established. Their literature suggests the device permanently seals vessels up to 3mm with less thermal damage, resulting in less intraoperative blood loss, more efficient procedures, and possibly less pain. In a pilot study of 186 patients, intraoperative blood loss was shown to be <1ml of blood loss in 71 cases (38.2%) and between 1 and 10ml of blood loss in 81 cases (43.5%). Post-operative hemorrhage rate of 4.3% is similar to rates described by other studies. BiZact tonsillectomy allows for a shortened operative time with a median time of 5.1 minutes. Other studies have shown other techniques to have a time duration of 21.6 minutes (electrocautery), 20.20 minutes (coblator), and 16.14 minutes (microdebrider). In off label use of the device at our institution, data from surgeons using the device showed that surgeons perceived a relative improvement in following compared to standard tonsillectomy: Less perceived thermal heat transfer to surrounding soft tissues Left perceived blood loss Superior ease of obtaining timely hemostasis Faster operative time

Tracking Information

NCT #
NCT04725305
Collaborators
Not Provided
Investigators
Not Provided