Recruitment

Recruitment Status
Recruiting
Estimated Enrollment
Same as current

Summary

Conditions
Acute Kidney Injury
Type
Observational
Design
Observational Model: CohortTime Perspective: Prospective

Participation Requirements

Age
Between 19 years and 80 years
Gender
Both males and females

Description

In the current clinical trial, systemic perfusion and oxygenation through hemodynamic variables such as cardiac index and mean arterial pressure, and central venous oxygen saturation (cvSO2) are monitored during surgery. However, it has not been studied whether the hemodynamic parameters and systemi...

In the current clinical trial, systemic perfusion and oxygenation through hemodynamic variables such as cardiac index and mean arterial pressure, and central venous oxygen saturation (cvSO2) are monitored during surgery. However, it has not been studied whether the hemodynamic parameters and systemic oxygen saturation adequately reflect the perfusion and oxygen saturation of the kidney. Although there are various new serum biomarkers that are known to reflect renal function or damage, they are not real-time monitoring of renal function because they take time and cost to collect and analyze. Near-infrared spectroscopy (NIRS) measures the distribution of oxygenated hemoglobin and deoxygenated hemoglobin in tissues by sending two different near-infrared wavelengths (730 and 810 nm) from the sensor. It is a device that can continuously monitor the oxygen supply-demand balance to a specific region non-invasively. NIRS is mainly used to measure the oxygen demand-supply balance of the cerebral tissue by attaching a sensor to the forehead in the surgical patient. Since it is known to be closely related to the reduction of cerebral oxygen saturation during surgery and the occurrence of postoperative cognitive dysfunction, it is used as an indispensable monitoring device to prevent neurological complications in heart surgery patients. Recently, with technological advances, it has become possible to measure oxygen saturation by attaching sensors to various body tissues other than the brain. When monitored with an NIRS sensor attached to the kidney, the relationship between renal oxygen saturation reduction and postoperative acute kidney injury (AKI) in children and adult patients undergoing heart surgery was reported. However, so far, the effects of systemic hemodynamic and oxygen saturation changes during the displacement of heart for coronary anastomosis during OPCAB on the oxygen saturation in the cerebral cortex and kidney, have not been studied. In addition, it is not known whether the cerebral cortical oxygen saturation (rcSO2), which is commonly used in heart surgery, can reflect the renal oxygen saturation (rrSO2). The purpose of this study is to evaluate changes in renal oxygen saturation (rrSO2) and its relationship with central venous oxygen saturation (cvSO2), cerebral cortical oxygen saturation (rcSO2), and hemodynamic parameters while displacing the heart for each coronary anastomosis in 19-80 year old adult patients receiving off-pump coronary artery bypass graft surgery (OPCAB) under general anesthesia.

Tracking Information

NCT #
NCT04679337
Collaborators
Not Provided
Investigators
Not Provided