Recruitment

Recruitment Status
Recruiting
Estimated Enrollment
Same as current

Summary

Conditions
  • Mechanical Ventilation Complication
  • Tracheostomy
Type
Interventional
Phase
Not Applicable
Design
Allocation: RandomizedIntervention Model: Parallel AssignmentMasking: Single (Investigator)Masking Description: masking of the intervention and control groups in the statistical analysis of the data, which will be represented as group 0 and 1, without identifying whether they are control or interventionPrimary Purpose: Supportive Care

Participation Requirements

Age
Between 18 years and 125 years
Gender
Both males and females

Description

Introduction: Tracheostomy is one of the most frequently required surgical techniques for the management of hospitalized patients in Intensive Care Units (ICU). This procedure is justified to facilitate the improvement of the patient, facilitate early rehabilitation, reduce sedation and analgesia re...

Introduction: Tracheostomy is one of the most frequently required surgical techniques for the management of hospitalized patients in Intensive Care Units (ICU). This procedure is justified to facilitate the improvement of the patient, facilitate early rehabilitation, reduce sedation and analgesia requirements, and reduce the length of stay in the ICU and the days of mechanical ventilation (MV). However, tracheostomy is associated with various complications, from mispositioning and accidental decannulation, to hemoptysis, tracheal fistulas, air leaks, and ventilatory difficulties. In a pre-post quasi-experimental study where the effect of the DYNAtraq technological innovation device on tracheostomy fixation and alignment was evaluated, it was found that it can correct 83% of cases, which contrasts with only 2% when they did not have the device. (p <0.01). This previous study allowed us to conclude that technological innovation through DYNAtraq is pertinent, relevant and effective to correct the position of tracheostomy tubes in patients hospitalized in the ICU and under mechanical ventilation. Objective: To evaluate the efficacy and safety of the DYNAtraq medical device to keep tracheostomy tubes in correct alignment and fixation in adult patients with tracheostomy hospitalized in the ICU and under invasive mechanical ventilation. Methodology: Randomized, controlled clinical trial (two-parallel arm), assigned in a 1: 1 ratio, in a sample of 74 patients mechanically ventilated in intensive care unit (37 in intervention group and 37 patients in control group). This study is conducted in two centers for intensive care patients in two Colombian cities and The patients randomized to the intervention group will have the external fixation system for the tracheostomy installed, which is a non-invasive plastic device, from the start of the tracheostomy to ventilatory weaning. Patients in the control group will receive the usual management of the tracheostomy given in ICU. To evaluate alignment , the cephalo-caudal (C-C) and lateral-lateral (L-L) angles will be evaluated through photographs and analyzed with the MY MEASURES application. The mean values of the angles were obtained in degrees and their 95% confidence intervals. Angular means were compared using the paired Student's t test. Expected Results: The DYNAtraq device is expected to be effective in improving the proper fixation, orientation, and alignment of the tracheostomy tube in mechanically ventilated patients, reducing the complications of lacerations, bleeding, decannulation, and respiratory infectious complications.

Tracking Information

NCT #
NCT04668742
Collaborators
  • Instituto Colombiano para el Desarrollo de la Ciencia y la Tecnología (COLCIENCIAS)
  • Plasticos de Santander Ltda PLADESAN
Investigators
Principal Investigator: Mauricio Orozco-Levi, Ph.D Fundacion Cardiovascular de Colombia- Hospital internacional de Colombia