Recruitment

Recruitment Status
Not yet recruiting
Estimated Enrollment
Same as current

Summary

Conditions
Abdominal Aortic Aneurysm
Type
Interventional
Phase
Not Applicable
Design
Allocation: N/AIntervention Model: Single Group AssignmentMasking: None (Open Label)Primary Purpose: Diagnostic

Participation Requirements

Age
Between 18 years and 125 years
Gender
Both males and females

Description

Introduction: Surgery for abdominal aortic pathology usually occurs in the setting of advanced cardiovascular disease. The repair can be relatively simple or complex with multiple steps including open repair, placing a stent with a catheter, and placing a complicated stent that allows for crossing v...

Introduction: Surgery for abdominal aortic pathology usually occurs in the setting of advanced cardiovascular disease. The repair can be relatively simple or complex with multiple steps including open repair, placing a stent with a catheter, and placing a complicated stent that allows for crossing vessels without occluding them. All these repairs require imaging follow up. Rationale: The most commonly accepted tool for follow up is Computed Tomography (CT) scan which involves ionizing radiation and potentially nephrotoxic iodinated contrast. Routine ultrasound with Doppler, CT, and MRI has all been employed utilizing various imaging protocols. Concerns over cost, potential nephrotoxicity of contrast agents and repeated radiation exposure has led to investigation of alternate imaging modalities such as contrast enhanced ultrasound (CEUS). CEUS also allows continuous (dynamic) or real-time monitoring of the aneurysm and endoleak throughout the study. Objectives: Aim 1: To determine the consistency/discrepancy of endoleak detection (positive/negative) for contrast enhanced ultrasound (CEUS) versus various phases of CTA versus delayed phase CTA. Aim 2 (Exploratory): To explore the consistency/discrepancy of endoleak type (type 1-5) between CEUS and delayed phase CTA. Aim 3 (Exploratory): To explore the consistency/discrepancy of endoleak source detected (positive/negative for each source) for type II endoleaks between CEUS and CTA. Aim 4 (Exploratory): Re-assess Aims 1-3 for the follow-up scans. The goal for this aim is to examine whether the consistency/discrepancy patterns discovered in Aims 1-3 can be repeated at the follow-up scans. Population: 40 patients who have undergone an EVAR or FEVAR for abdominal aortic aneurysms and are expected to have CTA as part of their standard of care will be enrolled in the study. Methodology: Patients will be evaluated with research contrast ultrasound at one month post-op, six months post-op and at one year. Data Analysis Plan: Binomial 95% confidence interval will be calculated for sensitivity and specificity. One- sided binomial test will be conducted to test whether the target sensitivity and specificity are superior to the null value, e.g. a minimal acceptable level of sensitivity and specificity. In detecting the rate of endoleak positive on CEUS or other phases of the CTA but negative on CTA in the delayed phase, we will compute Clopper Pearson Exact 95% confidence interval since such a rate could be small. To assess consistency of endoleak type (type 1-5) between CEUS and delayed phase CTA, Kappa coefficient will be used. In the situation with high agreement biased towards one endoleak type, or extremely unbalanced distribution of endoleak types, prevalence-adjusted bias-adjusted kappa coefficient (PABAK) (Byrt, Bishop, and Carlin 1993) will be used. The discrepancy of endoleak type between CEUS and delayed phase CTA will be reported as rate, for example percent of case rated as type 1 in CTA but type 2 in delayed phase, with Clopper Pearson Exact 95% confidence interval. SAS9.4 will be used for all statistical analyses.

Tracking Information

NCT #
NCT04615559
Collaborators
Not Provided
Investigators
Principal Investigator: Edward Grant University of Southern California