Recruitment

Recruitment Status
Not yet recruiting
Estimated Enrollment
Same as current

Summary

Conditions
  • Cataract
  • Ultrasound Therapy; Complications
Type
Interventional
Phase
Not Applicable
Design
Allocation: Non-RandomizedIntervention Model: Parallel AssignmentIntervention Model Description: The study includes participants with age-related cataract and healthy subjects as control groupMasking: None (Open Label)Primary Purpose: Diagnostic

Participation Requirements

Age
Between 50 years and 70 years
Gender
Both males and females

Description

This is a prospective, pivotal, non-blinded study. Fifty (50) participants will be recruited at the Coimbra Surgical Center of Portugal. The study will be conducted on subjects with age-related cataract, and on healthy subjects as control group. Since this is a pilot study, no sample size estimation...

This is a prospective, pivotal, non-blinded study. Fifty (50) participants will be recruited at the Coimbra Surgical Center of Portugal. The study will be conducted on subjects with age-related cataract, and on healthy subjects as control group. Since this is a pilot study, no sample size estimation has been implemented. The statistical power will be determined at the end of the study. Only per-protocol participants will be considered on statistical analysis. Procedures involved. The ultrasonic system (Experimental Medical Device - ESUS) works in A-scan mode, with an acoustic working frequency of 20 MHz. From the ultrasonic signals backscattered from the lenses, acoustic parameters will be extracted, and used for automatic algorithms implementation. This study will be implemented once. Slit lamp with LOCS III classification will be used as comparator. Contrast sensitivity test results will be used for incipient cataract detection, where slit lamp may present some limitations. Optical coherence tomography and specular microscopy will help on detecting postoperative complications; other complications identified by the physician will be also considered. Surgical parameters as phacoemulsification energy and surgical time will help on phacoemulsification energy evaluation. Safety assessment. The system uses an ophthalmic probe. There are not anticipated adverse events related to the procedures involved in the use of the ultrasonic system, or any other procedure in the protocol. The safety conditions will be monitored through the occurrence of unanticipated adverse events or serious adverse events. If these situations occur, the event will be reported to the competent authorities (in agreement with the current regulation) and the corrective actions will be implemented.

Tracking Information

NCT #
NCT04461912
Collaborators
Fundação para a Ciência e a Tecnologia
Investigators
Principal Investigator: Miguel Caixinha, PhD miguel.caixinha@gmail.com