Recruitment

Recruitment Status
Recruiting
Estimated Enrollment
Same as current

Summary

Conditions
  • Anesthesia Complication
  • Cardiac Pacemaker Electrical Interference
  • Cardiac Pacemaker Malfunction
  • ICD Malfunction
  • Surgery- Complications
Design
Observational Model: CohortTime Perspective: Prospective

Participation Requirements

Age
Between 18 years and 125 years
Gender
Both males and females

Description

Background: The number of worldwide implanted cardiac electronic devices (CIED) is increasing continuously. On the other hand, the number of (more and more complex) surgical and catheter based interventions in this population is increasing as well. Recommendations for peri-operative management are o...

Background: The number of worldwide implanted cardiac electronic devices (CIED) is increasing continuously. On the other hand, the number of (more and more complex) surgical and catheter based interventions in this population is increasing as well. Recommendations for peri-operative management are often based on older data from case reports and small collectives. Data especially in particular subpopulations is limited. Objective: The study aims to evaluate the peri-operative management and outcome of patients with implanted CIED undergoing non-CIED related surgery or catheter interventional procedures (ablation) in clinical routine. Data from the study are expected to provide evidence for recommendations improving perioperative management and device programming. Study design: bi-center, non-randomized, observational registry, retrospective data-collection, on-going prospective patient enrollment, descriptive statistics Centers: Klinikum Fuerth (dep. for Heart and Lung disease, section for clinical electrophysiology), Klinikum Nuernberg (dep. for Heart surgery). Patients and methods: Primary endpoint: number and type of peri-operative adverse device related events (ADE) - all complaints, adverse events and adverse device effects will be documented and classified according to the ISO/DIS 14155 - Clinical Investigation of medical Devices in Human Subjects - Good Clinical Practices with respect to their relationship to the surgical or catheter intervention and [Stark NJ. A New standard for medical device adverse event classification. J of Clinical Research Best Practices 2009; 5(12): 1-7]. Secondary endpoints: pre-interventional data (patient characteristics, data from CIED interrogation); peri-interventional data (type of surgery/intervention, anesthesiology techniques, any AE), post-interventional data (data from post-interventional CIED interrogation, need for reprogramming / device revision). Subpopulations: cardiac surgery, vascular surgery, catheter ablation, ICD and mode of therapy inhibition, CRT, automatic features Inclusion criteria: patients with implanted CIED undergoing non-CIED related surgical or catheter-based procedure, peri-procedural CIED interrogation, age >18 years Exclusion criteria: no implanted CIED, no data from peri-procedural CIED interrogation available. Patient enrollment: retrospectively from the clinical records beginning from 2008, further on-going prospective inclusion Data acquisition: Data will be collected in CRF´s from the patient's history, the computer based clinical information system / clinical records and data records from CIED interrogations Sample size: For the observational study, there is no pre-specified sample size. Data from more than 500 patients undergoing > 700 interventions are expected. Data security: Study related data are collected by the study investigators in an anonymous clinic-internal data-base, that is password protected. All investigators have to provide valid GCP training. Risk estimation: the study is observational and descriptive with anonymized data collection/analysis and therefore adds no risk to the study population

Tracking Information

NCT #
NCT04331249
Collaborators
Klinikum Nürnberg
Investigators
Principal Investigator: Dirk Bastian, MD Klinikum Fuerth, European Society of Cardiology, European Heart Rhythm Society