Recruitment

Recruitment Status
Not yet recruiting
Estimated Enrollment
Same as current

Summary

Conditions
General Anesthesia
Type
Interventional
Phase
Not Applicable
Design
Allocation: N/AIntervention Model: Single Group AssignmentMasking: None (Open Label)Primary Purpose: Device Feasibility

Participation Requirements

Age
Between 18 years and 125 years
Gender
Both males and females

Description

Endotracheal intubation is a highly professional technique, especially for emergency patients with shallow coma, closed teeth and awake, it is more difficult to intubate. If the operation is improper, it is easy to damage the wound, pharynx and teeth or stimulate the throat to produce choking, breat...

Endotracheal intubation is a highly professional technique, especially for emergency patients with shallow coma, closed teeth and awake, it is more difficult to intubate. If the operation is improper, it is easy to damage the wound, pharynx and teeth or stimulate the throat to produce choking, breath holding, laryngospasm, aggravating hypoxia and mucosal injury. At present, the data of endotracheal intubation show that even under the non-emergency state of routine operation, the success rate of the first endotracheal intubation is 70%, and the success rate of secondary intubation is 89%. Under the pre-hospital emergency, the success rate of first intubation of ambulancemen is less than 50%, which is much lower than that of professional physicians. Therefore, it is of great significance to simplify the labor intensity of anesthesiologists and improve the intelligence of clinical operation. In this study, the electromagnetic acousto-optic fusion navigation technology is used to make a half-helmet type multi-axis magnetic coupling driving navigation robot cover on the left side of the patient's head in the supine position, automatically feeding the guide core with the internal magnetic tip through the external guide tube and intubating the trachea to the pharynx, applying the attraction of the external magnet to the neck hyoid so that the magnetic tip of the guide core in the endotracheal intubation points to the glottis. With the help of internal and external magnetic attraction and moderate driving force to push the guide core into the tube first, electromagnetic induction detection and spot image analysis determine it, continue to use the magnetic coupling device to push the guide bar to the bifurcation protuberance of the trachea, fix the guide bar, push the trachea intubation to the appropriate position, and then exit the guide bar and inflate the balloon. Sputum suction robot that can perform the sputum suction of a nurse simply, safely and effectively. It can be equipped with a closed sputum suction tube commonly used in clinical practice for sputum suction. And through a wired connection, the operator can perform sputum suction through the control unit at a long distance. In order to ensure that the machine is suitable for different patients and to ensure the safety of use, our equipment can set different depths of tube inlet, tube inlet speed, tube withdrawal speed, and sputum suction mode, while the sputum suction robot performs the entire process of sputum suction In this case, there is no need to stop the oxygen supply to the patient, and the risk of iatrogenic damage to the patient by hypoxia is also reduced To realize the mechanization and integration of surgical anesthesia and airway management.

Tracking Information

NCT #
NCT04327076
Collaborators
Not Provided
Investigators
Principal Investigator: Yi Lv, MD First Affiliated Hospital Xi'an Jiaotong University Principal Investigator: Qiang Wang, MD First Affiliated Hospital Xi'an Jiaotong University