Recruitment

Recruitment Status
Recruiting
Estimated Enrollment
Same as current

Summary

Conditions
Gastroparesis
Type
Observational
Design
Observational Model: Case-OnlyTime Perspective: Prospective

Participation Requirements

Age
Between 18 years and 80 years
Gender
Both males and females

Description

During Phase 1, in a small cohort of 5-10 gastroparetic patients receiving GES therapy, we will determine the optimal multielectrode array (MEA) recording electrode configuration (e.g., surface area covered and electrode density) for the noninvasive measurement of gastric electrical stimulation (GES...

During Phase 1, in a small cohort of 5-10 gastroparetic patients receiving GES therapy, we will determine the optimal multielectrode array (MEA) recording electrode configuration (e.g., surface area covered and electrode density) for the noninvasive measurement of gastric electrical stimulation (GES) evoked compound nerve action potentials (CNAP) from the skin surface over the left and right cervical vagus nerve. During Phase 2, a study of 15-30 gastroparetic patients receiving GES therapy, we will use the optimal MEA configuration identified in Task 1 to measure and classify the vagal CNAP response signature (including the direction of travel and anatomical location of the strongest signal (e.g., to infer the anatomical course of the cervical vagus in each subject) with respect to subject-reported symptom scores via the 9-item Gastroparesis Cardinal Symptom Index (GCSI) survey. We will cross-reference these results with the preliminary results obtained with bipolar ECG electrodes. Phase 1: Subjects will complete a symptom survey questionnaire and Gastric Cardinal Symptom Index (GCSI) questionnaire. Two electrocardiography (ECG) electrodes will be placed on both sides of the neck overlying the area near the carotid pulse (which overlies the carotid artery in the neck on the side of your neck) where the vagus nerve is located.This is done in order to measure the vagal nerve electrical impulses in the neck (electrical signal travelling in the nerve). Two ECG electrodes will be placed on each of the arms and one on the chest for measurement of electrocardiogram (ECG) ( a test to measure the electrical activity of your heart). Three ECG electrodes may be placed on the stomach to measure the electrical activity of the stomach. After the placement of the electrodes, a 2-5 minute recording will be made.The GES device will be interrogated (data will be obtained) for the settings of the device and these will be recorded by the study team. After the recording, the electrodes will be removed from the neck and a newer kind of electrodes called as MEA (Multi electrode Array)) devices that contain multiple (tens to thousands of small electrodes) will be placed on either one, or both sides of the neck. This film will help capture the vagus signal from a large area and help define the path of the vagus nerve. After the placement of this film with small electrodes, another 2-5 minute recording will be made. The electrodes will then be removed and subject will be allowed to go home. The total time required for Phase 1 will be approximately an hour (60 minutes). Phase 2: Subject will complete a symptom survey questionnaire and Gastric Cardinal Symptom Index (GCSI) questionnaire. Multiple electrodes (MEA) will be placed on either one or both sides of the neck. One ECG electrodes will be placed on each of the arms, and one on the chest for measurement of electrocardiogram (ECG). Three ECG electrodes will be placed on the stomach to measure the electrical activity of the stomach. After the placement of the electrodes a 2-5 minute recording will be made. The GES device will be interrogated (data will be obtained) for the settings and these will be recorded by the study team. With the GES stimulator on, a 2-5 minute recording will be made. Then, the GES stimulator will be reprogrammed to deliver the signal at 50% of the original power, and another 2-5 minute recording will be made. Then, the device will again be programmed to deliver the signal at 25% of the original power setting on the device. Another 2-5 minute recording will be made. After this, the device will be reprogrammed to the original settings. The electrodes will then be removed and subject will be allowed to go home. The total time required for Phase 2 will be approximately an hour (60 minutes).

Tracking Information

NCT #
NCT04207996
Collaborators
Purdue University
Investigators
Not Provided