Recruitment

Recruitment Status
Recruiting
Estimated Enrollment
Same as current

Summary

Conditions
  • Hip Dysplasia
  • Hip Necrosis
  • Hip Osteoarthritis
Type
Observational
Design
Observational Model: Case-OnlyTime Perspective: Prospective

Participation Requirements

Age
Between 18 years and 70 years
Gender
Both males and females

Description

Investigation type: Premarket study to receive a CE marking, followed by post-marketing surveillance follow-up. Investigation design: Multi-centre, prospective, non-randomized, observational study Investigation objectives: The primary objective is to confirm the safety and efficacy of the H1 hip res...

Investigation type: Premarket study to receive a CE marking, followed by post-marketing surveillance follow-up. Investigation design: Multi-centre, prospective, non-randomized, observational study Investigation objectives: The primary objective is to confirm the safety and efficacy of the H1 hip resurfacing prosthesis by demonstrating non-inferiority of the cumulative percent success in subjects implanted with the H1 hip resurfacing compared to a literature reference rate of the Birmingham hip resurfacing (BHR). The secondary objective is to demonstrate superiority of the ceramic-on-ceramic H1 hip resurfacing prosthesis with its metal-free articulation compared to MoM hip resurfacing in the absence of metal ion release. Additional goals are to demonstrate non-inferiority of the ceramic-on-ceramic H1 hip resurfacing prosthesis compared to hip resurfacing with regard to patient reported outcome measures, objective clinical and functional outcomes, and radiological assessment. The primary endpoint is revision for any reason Secondary endpoints: Complication rate (adverse events and revisions) Toxicology (blood metal ion measurements) CT assessment (Implant migration) Patient Reported Outcome Measures (PROMs) Objective clinical and functional outcomes (Harris Hip Score, Gait Analysis) Radiological assessment (implant orientation, osseointegration) Background Information Total Hip Arthroplasty (THA) is one of the most successful surgical interventions. Replacement of an arthritic hip joint provides significant pain relief and improvement of hip function and mobility. Patients, even elderly people, are more active, have a better quality of life, less comorbidities and a longer life expectancy. The World Health Organisation (WHO) has declared THA the second best intervention, only preceded by cataract surgery, regarding cost effectiveness and quality of outcome. In patients older than 70 years, the overall survivorship of THA is more than 90% at 10 years and the best clinical results are obtained for THA as a treatment for osteoarthritis (OA). In this patient population, THA can thus be considered a lifelong solution. However, both survivorship and clinical results are much worse in young and active people. The reasons for this worse outcome are multiple. First of all, younger people usually have a more active lifestyle regarding work and sports. Secondly, the hip disorders leading to THA in a younger patient population are more difficult to treat. Congenital hip dysplasia is frequently associated with gross hip deformities, as may be the case in secondary traumatic OA. Bone stock may be jeopardised in cases of avascular necrosis of the femoral head (AVN) and rheumatoid arthritis (RA). Thirdly, a faster bone metabolism may play a role, but this remains to be elucidated. Modern hip resurfacing arthroplasty (HRA) was introduced to address the inferior survivorship and unsatisfactory clinical results with THA in young and active patients. The anatomical reconstruction of the joint has the potential to provide a better function and higher activity levels compared to THA. Hip resurfacings are inherently higher performing than total hip replacements because they preserve the flexibility of native femoral head and neck. Metal-on-Metal (MoM) hip resurfacings have been shown to be safe and effective in many patients. These patients have superior clinical function over patients with total hip replacements, with little or no wear at the bearing surface in comparison to hard on soft bearings. The two most serious complications following hip surgery are death and infection. Both of these are substantially rarer after hip resurfacing when compared to patients with a cemented total hip arthroplasty, which is often presented as the gold standard of hip replacement. However, patients with poorly positioned hip resurfacing implants, poorly designed implants and smaller sizes especially in females have reported progressive pain leading to early revision. This pain is commonly caused by one of two problems: either metal ion particles generated by excessive wear associated with adverse soft tissue reactions to metal debris or soft tissue impingement on the hard metal edges of the components. Despite these two problems, hip registries continue to show superior survivorship of hip resurfacing using a well-designed device in young and active males when compared to total hip arthroplasty. Higher metal ion levels have been found in whole blood, serum and urine of patients with MoM hip arthroplasties (THA and HRA) compared to preoperative values, and to THA with other bearing surfaces (metal-on-polyethylene, ceramic-on-polyethylene, ceramic-on-ceramic). Although MoM hip arthroplasty has been shown to produce less volumetric wear compared to metal-on-polyethylene, the wear debris consists of more numerous, small, nanometre size particles, which are ingested by macrophages. Contrary to polyethylene, metal particles and ions are not chemically inert but may have directly toxic, biological effects and may elicit hypersensitivity reactions in addition to the macrophage-driven, innate, foreign-body immune responses to particulate debris of any material. Consequently, concerns have been raised about the physiological consequences of metal release from MoM hip prostheses into the peri- prosthetic tissue and systemic circulation. By exchanging the metal material of the bearing with BIOLOX®delta ceramic, a better wearing and more inert material, the positive clinical performance aspects of MoM hip resurfacings are retained, while the main cause of early revision is removed. The anatomic shape of the contours of the devices may go some way to reducing the pain caused by soft tissue erosion, Thus, the H1 ceramic-on-ceramic hip resurfacing could be used for wider indications than the currently restricted group of large men. Patients with smaller head sizes, females and patients with metal sensitivity may all be candidates, enabling them the option to have a more conservative operation if appropriate. The H1 hip resurfacing design is innovative both in its anatomical shape and in the bearing couple materials as there is currently no all-ceramic bearing hip resurfacing implant in clinical use. Ceramic-on-ceramic THA has a proven track record with excellent survivorship results in the arthroplasty registries as well as low complication rates and good functional results from large clinical series. The materials have been thoroughly tested regarding biocompatibility, biomechanical and tribological characteristics, and have been used in over one million clinical cases over the last 11 years, confirming safety of the material. However, a mono-block ceramic acetabular component without a metal shell such as the H1 hip has not yet been used clinically. The concept requires investigation before it can be CE marked and marketed in Europe. The anatomical contoured edge of both the cup and the head reduces the incidence of psoas impingement. The iliopsoas tendon is stretched over the femoral head when the hip is extended. In the normal hip, the tendon runs over the front edge of the acetabulum, and femoral head, which it uses as a fulcrum giving some leverage advantage as the muscle contracts to lift the leg up when bringing the leg up into the bath or into a high car for instance. When the femoral head is resurfaced, the tendon has to rub over the hard edge of the resurfacing device. Until now, femoral resurfacing devices have had a symmetric rim, which tends to extend beyond the normal limits of a femoral head, particularly in female hips. This overhang can cause painful abrasion of the tendon. Most acetabular components are also symmetric in shape, unlike the natural acetabular rim contour, which has a recess where the tendon runs. The rim of the acetabular shell can also be a cause of tendon irritation. BIOLOX®delta is a zirconia toughened alumina (ZTA). Along with alumina (Al) and zirconia (Zr), this material also contains traces of chromium (Cr), strontium (Sr) and very low amounts of yttrium (Y). This ceramic has an 11-year history of worldwide use in hip arthroplasty, with an excellent track record. Ceramic-on-ceramic bearings consist of the hardest material with the lowest wear rate of all bearing couples used in hip arthroplasty. The very low volume of inert ceramic nanoparticles and the absence of elevated Cobalt (Co) and Cr ion levels in the bloodstream virtually abolishes the risk of adverse local tissue reactions (ALTR), allergic reactions and systemic cobalt toxicity which can complicate some MoM Hip replacements. BIOLOX®delta contains very small amounts of Cr, but Cr release from the material remains below the detection limit in the blood. Strontium ions are found in the blood of control patients without any implant and remain at similar background level in patients with BIOLOX®delta ceramic implants, Yttrium ions are not detected. BIOLOX®delta is a zirconia-toughened alumina ceramic with increased fracture strengths. The use of BIOLOX®delta has virtually eliminated the already low fracture risk of the older ceramic implants. The fracture risk in the arthroplasty registries and as assessed by the manufacturer CeramTec is now estimated at < 0.001%. Besides a significantly lower risk of mortality with hip resurfacing compared to conventional cemented total hip arthroplasty (THA), the use of BIOLOX®delta ceramic on ceramic bearings further reduces the risk of the most devastating complication associated with THA, i.e. periprosthetic infection . Because of a significant reduction in biofilm formation and adherence to ceramic surfaces (69%) compared to metal (92%) and highly cross-linked polyethylene (HXL PE) (100%), the risk of periprosthetic infection is significantly reduced, to <0.5% at 10 years compared to >1% with polyethylene bearings including HXL PE. The uncemented fixation of the H1 hip resurfacing is not novel. The porous ingrowth coating of plasma sprayed titanium and hydroxyapatite has been applied by a leading implant coating specialist (Medicoat AG, Mägenwil, Switzerland). Acetabular cups using these coatings are now standard products with more than 15 years of experience. Several metal-on-metal hip resurfacing designs for non-cemented use, have successfully been implanted in large series of patients. Ti ions may be released as part of the bone ingrowth process of the non-cemented hip of knee prosthesis, but Ti_ions from Titaniumdioxyde (TiO2) coatings or Titanium-aluminum-vanadium (TiAlV) hip or knee arthroplasty components are not associated with toxic, teratogenic or carcinogenic reactions.

Tracking Information

NCT #
NCT03326804
Collaborators
Imperial College London
Investigators
Principal Investigator: Justin P Cobb, FRCS Imperial College London